; GSD-Datei fuer Tool Temp MP988 Regler ; ------------------------------------- ; Anbindung als DP-Slave ; ; last Revision: 19.06.09 ; #Profibus_DP GSD_Revision = 1 ;19.05.2005 ; Vendor_Name = "Tool Temp AG" Model_Name = "TT MP988" Revision = "V1.2" Ident_Number = 0x0ABC Protocol_Ident = 0 ;Profibus DP Station_Type = 0 ;DP-Slave FMS_supp = 0 Hardware_Release = "Revision B" Software_Release = "102" ; 9.6_supp = 1 19.2_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 0 6M_supp = 0 12M_supp = 0 ; MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 ; Redundancy = 0 Repeater_Ctrl_Sig = 2 ;TTL 24V_Pins = 0 Implementation_Type = "Asic" Bitmap_Device = "TT_A1" ; Freeze_Mode_supp = 0 Sync_Mode_supp = 0 Auto_Baud_supp = 0 Set_Slave_Add_supp = 0 Min_Slave_Intervall = 10 ; Modular_Station = 1 Max_Module = 1 Max_Input_Len = 244 Max_Output_Len = 244 Max_Data_Len = 432 Modul_Offset = 0 ; Fail_Safe = 0 Slave_Family = 5 ;Controller Max_Diag_Data_Len = 10 ; ; Module="MP988 - IO"\ 0xE0,\ ; IN: Modus (INT16) 0xE0,\ ; IN: Target (INT16, 1/10 Deg. Celsius) 0xD0,\ ; OUT: Status (INT16, 1/10 Deg. Celsius) 0xD0,\ ; OUT: Cur_Temp (INT16, 1/10 Deg. Celsius) 0xD0,\ ; OUT: Cur_Flow (INT16, 1/10 l/min) 0xD0,\ ; OUT: Cur_Out (INT16, %) 0xD0 ; OUT: Cur_Alarm(INT16) EndModule ; End of GSD